Skip to content

Three-phase Hybrid Inverter, 5-10 kW

Potis Edge_LOGO

Maximizing Solar Energy Utilization

Three-phase hybrid inverters play a crucial role in enhancing the efficiency of home energy storage systems (ESS) and ensuring energy independence. These inverters enable optimal use of solar energy and efficient utilization of stored energy.

 

Fast energy transfer

Remote configuration
and updates

Integrated protection

Three-phase hybrid inverters
for maximizing solar energy utilization

Model range and integrated protection

Model Range and Performance – Three-phase hybrid inverters are available with a nominal AC output of 5-10 kW.

Integrated Protection – Built-in overvoltage and short circuit protection enhances system reliability and safety.

IP65 Protection – High-level protection against dust and water, making them suitable for outdoor use.

Outstanding efficiency
and performance

 

Maximum Efficiency – Up to 98.4% efficiency, ensuring minimal energy loss and maximum system efficiency.

High Charge/Discharge Current – 50A maximum charge and discharge current allows for fast energy transfer.

Remote Configuration and Updates – The system can be configured and updated remotely, simplifying maintenance and optimizing operation.

 

The Role of Inverters in Energy Storage Systems

The inverter is an essential part of energy storage systems as it converts the direct current (DC) generated by the solar panel system into alternating current (AC), which can be used by household appliances.

Additionally, the inverter is responsible for integrating the energy produced by the solar panels into household and grid systems.

Three-phase hybrid inverters provide an excellent solution
for reliable, efficient, and flexible energy storage and utilization

Ensure energy independence and cost efficiency for your home!

FAQ

Why should you choose a three-phase inverter?

Three-phase inverters provide more efficient energy transfer and allow for a more balanced energy distribution. Additionally, they offer higher performance, which may be necessary for larger households or industrial users.

What are the benefits of using three-phase inverters with energy storage systems?

Three-phase inverters increase the efficiency of energy storage systems, allowing households to optimally use the energy they produce, reducing energy costs and increasing energy independence.

How can a three-phase inverter be installed?

The installation of a three-phase inverter should be performed by a professional to ensure proper operation and safety. The installation process must consider the household's energy needs and the specifications of the electrical network.

What are the maintenance requirements for three-phase inverters?

Three-phase inverters require regular inspections and maintenance, including software updates and checking the condition of components to ensure optimal operation and a long lifespan.

How does Duna Watt assist in the installation and maintenance of three-phase inverters?

Our expert team helps with the installation and maintenance of three-phase inverters, ensuring the efficient and reliable operation of the system. We provide comprehensive support from installation to system updates and maintenance.

Sunnic DC Charging Station 50-80kw

Items
Parameters
Basic index
Rated power
50kW
60kW
80kW
Dimensions (wxdxh)
800mm x 500mm x 1800mm
Charging outlet
CSS2+CHAdeMO(optional), length; 5m
HMI
10.1 inch, color rouch screen
Installion
Ground mounted
Communication
EVSE
PLC(DIN 70121:2104-12 /ISO15118)
Back-end protocol
OCCP 1.6/OCPP 2.0 (upgradeable)
Method of Payment
Payment mode
Optional: RFID Card / POS
Input characterictics
Frequency
50 Hz
Power factor
>0.98 (50% ~ 100% load)
Harmonic
iTHD<5%
Output Characteristic
Voltage
DC 200~1000V
Current
CCS2 30OA max. CHAdeMO 125A max
Power
CSS2 120kW max. CHAdeMO 62.5kW max.
CSS2 150kW max. CHAdeMO 62.5kW max.
CSS2 160kW max. CHAdeMO 62.5kW max.
Peak efficiency
>95%
Charging way
Meantime
Environmental indicators
Operating tempreature
-30 °C ~ +50 °C
Relative humidity
5% – 95% without condensation
Working altitude
<2000M
Protection grade
IP54
Application site
Indoor / Outdoor
Cooling method
Inteligence air forced cooling
Noise
<60db
Markings
Certification
CE, CB, UKCA, TR25
Weight
Net weight
<330kg
Gross weight
<400kg

Sunnic DC Charging Station120-160kw

Items
Parameters
Basic index
Rated power
120kW
150kW
160kW
Dimensions (wxdxh)
850mm x 610mm x 2000mm
Charging outlet
CSS2+CHAdeMO(optional), length; 5m
HMI
10.1 inch, color rouch screen
Installion
Ground mounted
Communication
EVSE
PLC(DIN 70121:2104-12 /ISO15118)
Back-end protocol
OCCP 1.6/OCPP 2.0 (upgradeable)
Method of Payment
Payment mode
Optional: RFID Card / POS
Frequency
50 Hz
Power factor
>0.98 (50% ~ 100% load)
Harmonic
iTHD<5%
Output Characteristic
Voltage
DC 200~1000V
Current
CCS2 30OA max. CHAdeMO 125A max
Power
CSS2 120kW max. CHAdeMO 62.5kW max.
CSS2 150kW max. CHAdeMO 62.5kW max.
CSS2 160kW max. CHAdeMO 62.5kW max.
Peak efficiency
>95%
Charging way
Meantime
Environmental indicators
Operating tempreature
-30 °C ~ +50 °C
Relative humidity
5% – 95% without condensation
Working altitude
<2000M
Protection grade
IP54
Application site
Indoor / Outdoor
Cooling method
Inteligence air forced cooling
Noise
<60db
Markings
Certification
CE, CB, UKCA, TR25
Weight
Net weight
<330kg
Gross weight
<400kg

Sunnic DC Charging Station 180-240kw

Items
Parameters
Basic index
Rated power
180kW
240kW
Dimensions (wxdxh)
850mm x 800mm x 2000mm
Charging outlet
CSS2+CHAdeMO(optional), length; 5m
HMI
10.1 inch, color rouch screen
Energy master
MID
Installion
Ground mounted
Communication
EVSE
PLC(DIN 70121:2104-12 /ISO15118)
Back-end protocol
OCCP 1.6/OCPP 2.0 (upgradeable)
Method of Payment
Payment mode
Optional: RFID Card / POS
Input characterictics
Input voltage
400VAC ±10%, three-phase+N+PE
Frequency
50 Hz
Power factor
>0.98 (50% ~ 100% load)
Harmonic
iTHD<5%
Output Characteristic
Voltage
DC 200~1000V
Current
CCS2 30OA max. CHAdeMO 125A max
Power
CSS2 180kW max. CHAdeMO 62.5kW max.
CSS2 240kW max. CHAdeMO 62.5kW max.
Peak efficiency
>95%
Charging way
Meantime
Environmental indicators
Operating tempreature
-30 °C ~ +50 °C
Relative humidity
5% – 95% without condensation
Working altitude
<2000M
Protection grade
IP54
Application site
Indoor / Outdoor
Cooling method
Inteligence air forced cooling
Noise
<60db
Markings
Certification
CE, CB, UKCA, TR25
Weight
Net weight
<440kg
Gross weight
<530kg

Sunnic DC Charging Station 320-400kw

Items
Parameters
Basic index
Rated power
320kW
400kW
Dimensions (wxdxh)
850mm x 1100mm x 2100mm
Charging outlet
CSS2+CHAdeMO(optional), length; 5m
HMI
10.1 inch, color rouch screen
Energy master
MID
Installion
Ground mounted
Communication
EVSE
PLC(DIN 70121:2104-12 /ISO15118)
Back-end protocol
OCCP 1.6/OCPP 2.0 (upgradeable)
Method of Payment
Payment mode
Optional: RFID Card / POS
Input characterictics
Input voltage
400VAC ±10%, three-phase+N+PE
Frequency
50 Hz
Power factor
>0.98 (50% ~ 100% load)
Harmonic
iTHD<5%
Output Characteristic
Voltage
DC 200~1000V
Current
CCS2 30OA max. CHAdeMO 125A max
Power
CSS2 320kW max. CHAdeMO 62.5kW max.
CSS2 400kW max. CHAdeMO 62.5kW max.
Peak efficiency
>95%
Charging way
Meantime
Environmental indicators
Operating tempreature
-30 °C ~ +50 °C
Relative humidity
5% – 95% without condensation
Working altitude
<2000M
Protection grade
IP54
Application site
Indoor / Outdoor
Cooling method
Inteligence air forced cooling
Noise
<65db
Markings
Certification
CE, CB, UKCA, TR25
Weight
Net weight
<580kg
Gross weight
<710kg

KEEWAY - ALL-IN-ONE ENERGY STORAGE

Type
Storage
Solar + Storage
Battery Parameter
Cell Type
LFP Pristimatic Type
LFP Pristimatic Type
Battery Capacity (kWh)
50~200
50~200
Voltage Range (V)
250~800
320~800
Max. Charging Power (kW)
50/150
30/100
AC On-grid Parameter
Grid Type
3W+N+PE
3W+N+PE
Input / Output (kW)
50~150
50
AC Voltage (V)
320~460
320~460
Applicable Grid Frequency (Hz)
45~55/55~65
45~55/55~65
THDi
<3% (100% load)
<3% (100% load)
Power Factor
1(Leading)~1(Lagging)
1(Leading)~1(Lagging)
AC Off-grid Parameter
Rated Charge/Discharge Power(kW)
50~150
50
Max Output Power (kVA)
50~150
55
Rated A C Voltage (V)
400
400
Nominal Frequency􀊢Hz􀊣
50/60
50/60
≤ 1% linear; or ≤ 5% nonlinear
≤ 1% linear; or ≤ 5% nonlinear
Photovoltaic Input
Max Input Power (kW)
-50/100
MPPT Voltage Range (V)
250~850
General Parameter
Dimension:W*D*H (mm)
2200*1100*2340
2200*1100*2340
Max. Weight (kg)
3200
3200
IP Degration IP54
Operating Temperature Range (􀋆 )
-20~50
-20~50
Relative Humidity
0~95%(No condensation)
0~95%(No condensation)
Altitude
<2000m
<2000m
Cooling Method
Heat Ventilation Air Conditioner
Heat Ventilation Air Conditioner
Noise (dB)
≤ 75
≤ 75
System Efficiency
≥ 85%
≥ 85%
Firefighting System
Intetared
Intetared
Communication
Ethernet, Modbus TCP/IP
Ethernet, Modbus TCP/IP
Certification
Safety & Certification
IEC62619, UN38.3
IEC62619, UN38.3

Duna Watt Electric Car Charger, 11 kW

TECHNICAL DATA

Input voltage: 400VAC 50/60Hz 3 phase
Output voltage: 400VAC 50/60Hz 3 phase
Max current: 16A
Max power: 11KW
Input frequency: 50Hz / 60Hz
Charging interface: Type 2 IEC 62196
Cable length: 5m

WORKING ENVIRONMENT

Safety: Overvoltage protection, undervoltage protection, overload protection, leakage protection, grounding protection, over-temperature protection, lightning protection
Type B
IP degree: IP55
Operating temperature: -25°C~+50°C
Indoor/Outdoor

WARRANTY

Warranty: 24 Months
Certificate: CE

OTHER

Product size: 320*190*103 mm
Net weight: 4-6kg
Color: white
Manufacturer: ELECTRLY
Category: wall charger

Contact

Get in touch with us to find the best solution together!

Keeway - ZBOX200 Energiatároló

Type
ZBox200
Battery Parameters
Voltage Range(V)
250~800
Rated Capacity(Ah)
280
Rated Charge/Discharge Current(A)
140/140
Rated Energy(kWh)
50~200
Maximum Discharge Current(A)
200
Maximum Charge Current(A)
200
General Parameter
Dimension:W*D*H (mm)
1100*1100*2340
IP Grade
IP54
Total Weight (kg)
Max.2300
Cooling Mode
HVAC
Fire Fighting
Integrated
Operating temperature (C )
-20~ 50
Operating humidity
5%~95%R.H
Communication
CAN/RS485 / Modbus TCP/IP
Parallel
Max.10 cabinets
Certification
Safety & Certification
IEC62619
Transportation
UN38.3